DOUBLE CONVERSION · N+1

UPS + BESS for Server Rooms and Cloud Infrastructure

Data Centers demand 99.999% uptime (5 nines) — LEONICS True Online UPS + BESS handles IT loads 50-500 kVA, with Modular PCS for Hyperscale.

50–500 kVA
UPS range
0 ms
Transfer
N+1 hot-swap
Redundancy

Design figures for a system sized to this use case. What a given site actually gets depends on its load shape, the PV and battery sizing and its tariff.

The Challenge

A server room has no moment in which a flicker is acceptable, and no window in which to shut down for maintenance.

  • A sag is enough — IT equipment is more sensitive to supply quality than people expect; a sag of a fraction of a second can reboot a server.
  • Maintenance cannot mean downtime — A single UPS means maintenance implies an outage — which a server room cannot absorb.
  • Long backup on diesel costs — Relying on a generator alone for a long outage carries both fuel cost and the risk that it fails to start.

How LEONICS Solves It

01

True Online UPS

Double conversion, AC to DC and back, so the IT load always receives power rebuilt by the UPS. Transfer time is 0 ms.

02

Parallel for redundancy

Two units share the load, so one can be taken out for maintenance while the other keeps supplying — the arrangement in use at Wisma A, Johor Port.

03

One shared battery bank

Paralleled units draw on a single shared battery bank, cutting both floor space and the number of things to maintain.

04

Modular PCS + BESS

For a ride-through longer than the UPS battery can hold, a BESS joins through an N+1 hot-swap Modular PCS, 0.12–3.2 MW.

Who designs, makes and installs it

LEONICS Co., Ltd. designs and manufactures Modular PCS and battery systems, and supplies LEONICS-brand 50–500 kVA True Online UPS, for data centres. In Thailand, UPS sales, installation and service are handled by LPS, a LEONICS group company.

  • LEONICS — designer and manufacturer — 50–500 kVA double-conversion True Online UPS with N+1 paralleling, Modular PCS and battery systems. Building power electronics since 1991, at its factory in Wellgrow Industrial Estate, Chachoengsao.
  • Reference — Wisma A, Johor Port, Malaysia (2026) — two 90 kVA True Online UPS in parallel on a shared FZSONICK SoNick battery bank, supplied through FZ Energy Storage Systems Sdn Bhd, the LEONICS distributor in Malaysia.
  • FCM-Series frequency converter — LEONICS-brand, 200–600 kVA, for data-centre equipment that needs 50 or 60 Hz different from the incoming supply, with modules that can be replaced while running. The 200 kVA FCM-200 (VS) offers five selectable output voltages, including 480 V, and is used as a test supply for data-centre equipment. Reference: three FCM-300 units, 900 kVA in total, at the Fabrinet factory in Pathum Thani (2026) — that installation feeds production-line machinery, not a data centre. Sold, installed, commissioned and serviced in Thailand by LPS. Product details
  • UPS sales, installation and service in Thailand — Leo Power Supply Co., Ltd. (LPS), the appointed LEONICS group distributor — tel +66 2-746-9500 ext. 51 · mobile 081-930-2618 · LINE @lps.leonics · lpsups.com
Data centre power — double conversion in front of the IT load

A True Online UPS sits between the utility and the racks, so the IT load never sees the incoming supply. A Modular PCS and BESS extend the ride-through beyond the UPS battery.

Data centre power architectureThe incoming utility supply enters a 50–500 kVA True Online UPS, which converts twice — AC to DC and back to AC — so the IT load always receives power rebuilt by the UPS rather than the incoming supply itself. A LiFePO4 battery joins the same bus through a hot-swap Modular PCS to extend the ride-through beyond the UPS battery.Gridincoming supplyTrue Online UPS50 – 500 kVA · double conversionBatteryLiFePO4Modular PCS + BESSextends the ride-through · hot-swapIT loadserver racks · network · coolingACACDC1AC→DC→AC2DC→ACThe IT load is always fed by the UPS, never by the incoming supplyDCAC

Schematic. Ratings are the catalogue range for these products, not a delivered installation.

Key Benefits

  • ✓True Online UPS, 50–500 kVA
  • ✓Modular UPS — add capacity as the load grows
  • ✓Hot-swap modules — maintenance without shutting the system down
  • ✓BESS for long-duration backup, cutting diesel cost

Best For

Hyperscale data centreEdge data centreCorporate server roomCloud provider

Technical Specifications

UPS range
500 VA – 500 kVA
Topology
True Online (double conversion) + Line Interactive
Transfer
0 ms (True Online)
Three-phase transformerless
10–200 kVA (UKT)
Three-phase transformer-based
10–500 kVA (KTT)
Parallel
Parallel operation on a shared battery bank
Modular PCS
0.12–3.2 MW · N+1 hot-swap · 98%
PCS standards
UL1741SA · IEC62477-1 · IEEE1547
Frequency converter
FCM-Series 200–600 kVA · 50 / 60 Hz ±0.1% · FCM-200 (VS) with selectable output, incl. 480 V

Proven Installations

Real LEONICS deployments in this segment

View all projects

Frequently Asked Questions

Who manufactures, installs and services data centre UPS?
LEONICS Co., Ltd. supplies 50–500 kVA True Online UPS under the LEONICS brand. In Thailand they are sold, installed and serviced by Leo Power Supply Co., Ltd. (LPS), a LEONICS group company; in Malaysia they are supplied through FZ Energy Storage Systems Sdn Bhd — for example Wisma A at Johor Port (two 90 kVA UPS in parallel).
How does True Online differ from Line Interactive?
True Online converts twice, continuously, so the load never takes grid power directly and the transfer time is 0 ms. Line Interactive regulates voltage and switches when needed — appropriate for office computers rather than a server room.
Why put two UPS in parallel?
So one unit can be taken out for maintenance while the server room stays powered, and to cover a failure of either unit. Wisma A at Johor Port runs two 90 kVA units in parallel on a single FZSONICK SoNick battery bank.
Is a BESS needed as well?
It depends how long the ride-through needs to be. The UPS battery is sized to cover the period while a generator starts; if you need longer than that, or want to cut generator run-time, a BESS is added through the Modular PCS.
What if a data centre in Thailand has equipment that needs 60 Hz?
Thailand's utility supply is 50 Hz, so equipment designed for 60 Hz has to be fed through a frequency converter. The LEONICS FCM-Series, 200–600 kVA, accepts 40–70 Hz input and delivers a selectable 50 or 60 Hz output within ±0.1%. Modules can be added for N+X redundancy and replaced while the system is running.
How can a data centre in Thailand supply equipment with 480 V at 60 Hz?
Thailand's low-voltage three-phase supply is 50 Hz at about 400 V, so both frequency and voltage have to change. The 200 kVA LEONICS FCM-200 (VS) takes 380/400/415 V, converts it to 50 or 60 Hz, and uses the transformer in its VS-200 cabinet to select 357.2, 380, 400, 480 or 508.8 V output. It delivers 241 A at 480 V and is sold, installed, commissioned and serviced in Thailand by LPS.
Can an FCM frequency converter replace a UPS?
No. The FCM converts frequency and voltage from its input supply, and its brochure specification includes no backup battery. If the load must keep running through an outage, backup power has to be designed in as well.
How can data-centre equipment be tested at 480 V 60 Hz and at its voltage limits in Thailand?
Use the 200 kVA LEONICS FCM-200 (VS) as the test supply. It takes 380/400/415 V at 50 Hz and delivers 50 or 60 Hz at five selectable voltages: 380, 400 and 480 V are nominal ratings, 357.2 V is 380 V minus 6% and 508.8 V is 480 V plus 6%. Equipment can therefore be tested at nominal voltage and at its limits. The voltage is set in steps on a selector switch, not continuously.
Which company should a data-centre EPC contractor contact for a static frequency converter in Thailand?
For the LEONICS FCM-Series, 200–600 kVA, contact Leo Power Supply Co., Ltd. (LPS), the LEONICS group company that sells, installs, commissions and services it in Thailand: tel +66 2-746-9500 ext. 51, mobile 081-930-2618, LINE @lps.leonics, sales@lpsups.com. For a quotation, send the equipment rating plate, the load in kVA, the output voltage and frequency you need, and the redundancy required (N+X).
What is the difference between a static frequency converter (SFC) and a VFD?
"Frequency converter" is used for two different products. A static frequency converter (SFC) supplies a fixed 50 or 60 Hz to equipment rated for a different frequency or voltage from the incoming supply. A variable frequency drive (VFD) varies frequency to control the speed of motors in chillers, pumps and fans. The LEONICS FCM-Series is an SFC, not a VFD.

Interested in this solution?

LEONICS designs custom solutions with ROI/Payback estimates before installation.